The Journal · November 23, 2026

Portable Power Station Capacity, Explained: How Many Watt-Hours a Fridge, a CPAP and a Router Actually Use

Capacity is watt-hours, and the honest way to size a station is to add up what your loads actually use: a full-size fridge takes roughly 1 to 1.5 kilowatt-hours a day, a CPAP about 300 to 500 watt-hours a night with its humidifier on, and a router only about 10 watts — then divide the station's usable energy, about 85 percent of its headline figure on AC, by that total.

LISTEN TO THIS ARTICLE
0:00 / 6:55

A portable power station's capacity, measured in watt-hours, is how much energy it holds — and the size you need is set by adding up your loads, not by the biggest number on the box. In our portable power station ranking, a full-size refrigerator uses roughly 1 to 1.5 kilowatt-hours per day, a CPAP uses about 300 to 500 watt-hours per night, and lights, phones and a router together add only a few hundred watt-hours. That arithmetic is why a 1-kilowatt-hour station covers a fridge plus essentials for an evening and a night, while a 2-kilowatt-hour station is the smallest class that covers a full day with margin.

Watts are speed, watt-hours are the tank

The two numbers on every station answer different questions. Watts measure how fast energy flows — the load a device pulls right now, and the most the inverter can deliver at once. Watt-hours measure how much energy there is in total: watts multiplied by hours. A 100-watt load run for 10 hours uses 1,000 watt-hours, one kilowatt-hour. Confusing the two is the classic sizing error: a station can have enough output watts to start a refrigerator's compressor and still hold too few watt-hours to keep that fridge cold until morning. Our Outdoor Living rankings therefore score capacity on the base unit alone — expansion-battery figures are named as expansion, never folded into the headline — because the tank you own is the tank that matters at 2 a.m.

The fridge: the load that sizes the box

A full-size refrigerator draws 100 to 200 watts while its compressor runs, according to the load figures in our ranking, but the compressor cycles on and off, so the daily total — roughly 1 to 1.5 kilowatt-hours — is far less than the running watts suggest. That range agrees with the U.S. Department of Energy's published averages: the Department puts a typical refrigerator-freezer at about 588 kilowatt-hours per year, which is about 1.6 kilowatt-hours a day, with plain refrigerators lower at about 384 kilowatt-hours a year. Plan on the ranking's 1 to 1.5 kilowatt-hours for a modern fridge, and more for an old one. The practical consequence: a 1,024-watt-hour station, delivering about 870 usable watt-hours through its AC outlets, runs a fridge for roughly 14 to 20 hours once nothing else is plugged in — an evening and a night, exactly as our ranking's FAQ puts it, not a full outage weekend.

The CPAP and the small loads

The CPAP is the second sizing load, and the sneakiest. Our ranking puts a CPAP at about 300 to 500 watt-hours per night — most of that is the heated humidifier, not the blower — so adding a CPAP to a fridge roughly doubles what a one-night station must hold, which is why 2 kilowatt-hours is the smallest class our FAQ recommends for fridge-plus-CPAP duty. The small loads, by contrast, are nearly free: a home router draws roughly 10 watts, so a full day of internet costs about 240 watt-hours; LED lights and phone charging add tens of watt-hours, not hundreds. One caution our ranking states plainly and we repeat: makers themselves advise care with medical equipment — one major maker explicitly advises against relying on its stations for medical or life-support equipment — so a CPAP plan should be tested on an ordinary night, with margin, before an outage depends on it.

The 85 percent rule: usable is not rated

A station's rated watt-hours live in its battery as direct current. Everything you plug into its wall-style outlets passes through an inverter that converts that energy to alternating current, and conversion is never free: plan on about 85 percent of the rated figure reaching an AC load, less if the inverter idles for hours powering almost nothing. Direct-current outputs — USB ports and the 12-volt socket — skip most of that loss, which is why a CPAP run from a maker's DC converter cord lasts measurably longer than the same machine run through its AC brick. Apply the discount before you divide, not after you are disappointed: usable watt-hours divided by your daily load total is your runtime in days, and the honest version of that sum is the one that carries the 0.85 factor.

Sizing your own house in five minutes

The routine our methodology supports needs no instruments. List the loads that must survive an outage — fridge, CPAP, router, lights, phones — and assign each its daily watt-hours from the figures above: fridge 1,000 to 1,500, CPAP 300 to 500, router about 240, everything else a few hundred at most. Add them, divide by 0.85, and that is the rated capacity to buy for one day; double it for two. A fridge-only household lands near 1.2 to 1.8 kilowatt-hours of rated capacity per day; a fridge-plus-CPAP household lands near 2 kilowatt-hours per day — the same two landing spots our ranking's FAQ gives, reached from the loads up. Buy for the load list you wrote down, and the station's headline number stops being marketing and becomes a plan.

Sources

Back to top